Power & cooling for AI data centres

AI data centres are limited by how much electricity they can get and how much heat they can remove.

Layer 1 · Physical & Energy · Build and run time · reviewed 2026-10-30

SimpleA plain explanation, one diagram and an analogy, with where the analogy breaks.

Guess first: Feel your legs after a run. What do busy computers need to stay cool?

Show the answerLots of cooling: big fans and cold water. And lots of electricity, for the work and the cooling.

Computers get warm when they work hard, like your legs when you run. AI computers work very hard, all day and all night. So they need lots of electricity and lots of cooling.

Building one is a bit like building the power and air-conditioning for a small town. And it all goes to one room full of very busy computers.

Almost all the electricity a chip uses turns into heat, so getting power in and getting heat out are two sides of the same problem.

AI racks pack far more power into the same floor space than traditional server racks, which is why new facilities increasingly move from air cooling to liquid cooling.

Where a data centre can be built is often decided by grid connection capacity and permitting time, not by land.

Gridpower supply1Substationplus backup2Rackschipscompute3Heatnearly allenergy4Coolingair orliquid5Releasedair or water6
Power in, heat out
  1. Grid: power supply
  2. Substation: plus backup
  3. Racks: chips compute
  4. Heat: nearly all energy
  5. Cooling: air or liquid
  6. Released: air or water

Like: Like a stadium on match day: the challenge isn't just building it, it's getting enough power in and enough heat out.
Where it breaks: A stadium peaks for a few hours. AI clusters run near full load around the clock, so they need steady supply, not just peak capacity.

ResearchWhere the simple picture breaks, open problems and primary sources.

The Simple explanation explains power and heat for one building. Summed across a country, the totals, the sources of supply and the side effects are all contested.

How much demand. The IEA's base case has global data-centre electricity rising from about 415 TWh in 2024 to around 945 TWh in 2030, and its 2035 cases span roughly 700 to 1,700 TWh (IEA, 2025).

Efficiency versus growth. US data-centre use stayed near 60 TWh from 2014 to 2016 as efficiency offset growth, then reached 176 TWh, 4.4% of US electricity, in 2023. Whether efficiency can catch up again is unresolved (Berkeley Lab, 2024).

Who supplies it. Builders look at on-site generation or sharing a site with an existing power station. US regulators are still deciding how such co-located loads should pay for, and lean on, the wider grid (FERC, docket RM26-4).

Water. Cooling towers evaporate water on site and power stations use more off site, with no agreed way to count both. One projection puts AI's global water withdrawal at 4.2 to 6.6 billion cubic metres in 2027 (Li et al., 2023).

Security on this concept: 2 threats Pending expert review

Model weights copied out by insiders or intruders Pending expert review

Exposed
  • Weight files on servers and storage in data centres and labs
  • Staff, contractors and partners who are given access to them
Attacks
  • An insider or trusted recipient copying weights and sharing them
  • An intruder using stolen credentials to download weights from storage
Real case
Incident: Restricted research model weights leaked publicly a week after release (LLaMA) (2023-03)
Controls
  • Give as few people and systems as possible read access to weights; two-person rules for bulk copies
  • Encrypt weights at rest with keys held in hardware security modules
  • Alert on large or unusual downloads from weight storage
Owner
CISO, with ML engineering
Reference
AML.T0035 AI Artifact Collection
AML.T0025 Exfiltration via Cyber Means
AML.T0048.004 AI Intellectual Property Theft

Break-ins and tampering at data-centre sites Pending expert review

Exposed
  • Buildings, cages and racks that hold servers and model weights
  • Power and cooling controls the servers depend on
  • Maintenance and visitor access
Attacks
  • Unauthorised entry to rooms that hold weight-bearing servers
  • Planting devices on racks or networks
  • Insiders misusing physical access
Real case
No documented public incident yet
Controls
  • Layered physical access with logging and escorts
  • Two-person rules for racks that hold model weights
  • Tamper-evident seals and camera coverage of sensitive cages
  • Separate, monitored networks for building controls
Owner
CISO, with Platform/Cloud
Reference
None verified

All layers in the security view

Examples as of 2026-10-30

Sources

  1. Energy and AI (IEA report) (2025)
  2. 2024 United States Data Center Energy Usage Report (Lawrence Berkeley National Laboratory) (2024-12-19)
  3. IEA: Energy and AI, executive summary (2025)
  4. Berkeley Lab: 2024 United States Data Center Energy Usage Report (full report) (2024-12-19)
  5. FERC: Interconnection of Large Loads to the Interstate Transmission System, Docket RM26-4 (2026)
  6. Making AI Less 'Thirsty': Uncovering and Addressing the Secret Water Footprint of AI Models (Li et al.) (2023-04-06)

How it connects

More in Layer 1 · Physical & Energy